09FIRE PROTECTION

Fire Protection & Fire Sprinkler Water Storage Tanks

A dedicated fire water reserve for hydrant and automatic sprinkler systems — sized from your fire protection design and coordinated with the fire pump set.

  • Dedicated fire reserve
  • Sized from your design
  • Ground, elevated or terrace
Galvanised AVM tank with a fire pump house and red fire piping on a paved yard
Tank with fire pump house
Overview

A reserve kept for one job

A fire protection water storage tank holds the water a building or site sets aside for firefighting. Keeping that reserve dedicated — rather than drawn down by daily use — is central to most fire safety designs.

Automatic sprinkler systems also need a reliable supply for the duration set in their design. Where mains supply alone cannot provide that, a dedicated tank holds the required volume for the sprinkler pumps.

AVM Prefabricated Modular Tanks LLP supplies prefabricated steel tanks for both duties at commercial buildings, residential developments, institutions and industrial sites. Capacity, location and connections follow the design prepared by your fire consultant.

Key features

Key features of fire protection & sprinkler tanks

Dedicated fire reserve

Tank planned to hold the fire water volume in your design.

Pump suction planning

Outlets positioned for fire and sprinkler pump suction and hydrant mains.

Level visibility

Level indication options so the reserve can be checked.

Inspection access

Ladders, manholes and openings for periodic inspection.

Covered tank

Roofed construction keeps debris away from pump suctions.

Drawing support

Foundation drawings and layout options for your team.

Applications

Where fire protection & sprinkler tanks are used

Applications to be confirmed with AVM for each project include:

  • Warehouses & distribution centres
  • Manufacturing plants
  • Commercial buildings & malls
  • Residential towers & townships
  • Hospitals & institutions
  • Hotels
  • Industrial units
Advantages

Planning around the fire system

01

Design-led volume

Storage is set by the hydrant and sprinkler design rather than guessed.

02

Clean suction

A covered tank and planned outlets protect the pump set.

03

Fits the site

Tanks can be planned for ground level, elevated platforms or terraces.

Selection guide

Information your fire designer will provide

The fire protection design sets the tank — not the other way round. Before ordering, confirm:

Applicable standards, capacity ranges and system compatibility are confirmed by AVM for each project. No certification is implied.

Consider these factors

  • Required flow and supply duration (hydrant and/or sprinkler)
  • The design standard, local fire authority or insurer requirement
  • Whether a combined or separate reserve is needed
  • Pump set arrangement and suction requirements
  • Tank location, refill and level-monitoring arrangements
Technical specifications

Specifications at a glance

Final values are confirmed per project against your drawings and site conditions.

Fire Protection & Fire Sprinkler Water Storage Tanks — technical specifications
Product typeFire Protection & Fire Sprinkler Water Storage Tanks
Storage capacity28 KL - 800 KL
Tank constructionPrefabricated, bolted modular steel panels; cylindrical tank
Panel / material detailsGI
Coating detailsPre-painted steel panel options
Liner details760 GSM to 800 GSM liner
InstallationOn-site assembly. Support with foundation drawings and layout options
Applicable standardsFire Protection & Fire Sprinkler Water Storage Tanks
Warranty5 Years
Gallery

AVM tanks on site

Photographs of AVM tank installations for this type of application. Select a photo to enlarge.

Why AVM

Why Choose AVM?

AVM provides prefabricated fire water tanks and works from your consultant’s fire protection and sprinkler drawings to plan capacity, position and connections.

We support your team with foundation drawings and layout options for the tank and its pump room interface.

Prefabricated modular tanks Foundation drawing support Factory at Bhor, Pune
01 Consult & size Application, demand and site reviewed to fix capacity and material.
02 Foundation drawings Drawings and layout options for your civil team.
03 Factory-made panels Panels and fittings produced off site.
04 Bolt-up & handover Erection, testing and handover of the tank.
FAQs

Frequently asked questions

A tank that holds a dedicated water reserve for a building or site’s firefighting system, such as hydrants and sprinklers.

A tank that stores the water an automatic sprinkler system needs for its design duration, supplying the sprinkler pumps.

From the fire protection design: the required flow multiplied by the supply duration set by the applicable standard, fire authority or insurer.

That depends on the fire protection design and local requirements. Your fire consultant decides whether a combined or separate reserve is needed.

No certification is implied. Any approval required by your project must be confirmed and documented for the specific product.

Request a quote

Planning fire water storage for hydrants or sprinklers?

Share your fire protection design with AVM for a tank proposal.

Enquiry for: Fire Protection & Fire Sprinkler Water Storage Tanks

Fields marked * are required. We use your details only to respond to this enquiry.